Wire size chart: AWG, mm², OD and colours

Gauges, outside diameters and colour codes for harness wire, each value with its source and the date we read it.

No account. Nothing is stored. · Last updated

In short

An AWG size is a diameter of solid copper; mm² is a cross-section. 20 AWG is 0.518 mm² of copper, 18 AWG 0.823 mm², 16 AWG 1.31 mm²: none of them equals a metric size, so a drawing that mixes the two needs a choice, not a conversion. Outside diameters differ between wire types of the same size (thin-wall FLRY against TXL, GXL and SXL), and between makes within the same standard — use the maker's sheet for the wire you buy.

Worked example

20 AWG = 0.518 mm² · 18 AWG = 0.823 mm² · 16 AWG = 1.31 mm² · 14 AWG = 2.08 mm² · 12 AWG = 3.31 mm²

Convert

By area, from the AWG definition (ASTM B258 formula). Not a rule for substituting one size for another.

Copper area
0.823 mm²
Solid diameter
1.024 mm
Nearest gauges by area
19 AWG (0.653 mm²) · 18 AWG (0.823 mm²)

AWG to mm² (solid conductor)

AWGDiameter (mm)Area (mm²)
4/011.684107
3/010.40585
2/09.26667.4
1/08.25153.5
17.34842.4
26.54433.6
35.82726.7
45.18921.2
54.62116.8
64.11513.3
73.66510.5
83.2648.37
92.9066.63
102.5885.26
112.3054.17
122.0533.31
131.8282.62
141.6282.08
151.451.65
161.2911.31
171.151.04
181.0240.823
190.9120.653
200.8120.518
210.7230.41
220.6440.326
230.5730.258
240.5110.205
250.4550.162
260.4050.129
270.3610.102
280.3210.081
290.2860.064
300.2550.051
310.2270.04
320.2020.032
330.180.025
340.160.02
350.1430.016
360.1270.013
370.1130.01
380.1010.008
390.090.006
400.080.005

Source: en.wikipedia.org (2026-10-30)

Outside diameter by wire type

Values as each maker or distributor states them; inch values converted (× 25.4). Other makes of the same type differ within the standard's limits.

FLRY-B — ISO 6722-1 · PVC · -40 to +105 °C (3000 h)
Sizemm²AWGStrandingOD min (mm)OD nom. (mm)OD max (mm)Wall (mm)
0.350.35—12x0.211.2—1.4—
0.50.5—16x0.211.4—1.6—
0.750.75—24x0.211.7—1.9—
11—32x0.211.9—2.1—
1.251.25—38x0.212.1—2.3—
1.51.5—30x0.262.2—2.4—
22—28x0.312.5—2.8—
2.52.5—50x0.262.7—3—
33—44x0.313.1—3.4—
44—56x0.313.4—3.7—
55—70x0.313.9—4.2—
66—84x0.314—4.3—

Source: na.prysmian.com (2026-10-30)

FLRY-A — ISO 6722-1 / LV 112-1 (conductor acc. to LV 112-1 and ISO 6722-1, as stated by source) · PVC · -40 to +105 °C (3000 h)
Sizemm²AWGStrandingOD min (mm)OD nom. (mm)OD max (mm)Wall (mm)
0.220.22—7x0.211.1—1.2—
0.350.35—7x0.271.2—1.3—
0.50.5—19x0.201.4—1.6—
0.750.75—19x0.241.7—1.9—
11—19x0.271.9—2.1—
1.51.5—19x0.332.2—2.4—
2.52.5—19x0.412.7—3—
44—37x0.383.4—3.7—
66—37x0.454—4.3—

Source: na.prysmian.com (2026-10-30)

TXL — SAE J1128 · XLPE (cross-linked polyethylene) · -51 to +125 °C
Sizemm²AWGStrandingOD min (mm)OD nom. (mm)OD max (mm)Wall (mm)
22 AWG (7/30)—227/30—1.57—0.406
20 AWG (7/28)—207/28—1.78—0.406
18 AWG (16/30)—1816/30—2.01—0.406
16 AWG (19/29)—1619/29—2.26—0.406
14 AWG (19/27)—1419/27—2.62—0.406
12 AWG (19/25)—1219/25—3.2—0.457
10 AWG (19/23)—1019/23—3.94—0.508

Source: awcwire.com (2026-10-30)

GXL — SAE J1128 · XLPE (cross-linked polyethylene) · -40 to +125 °C
Sizemm²AWGStrandingOD min (mm)OD nom. (mm)OD max (mm)Wall (mm)
20 AWG (7/28)—207/28—2.13—0.584
18 AWG (16/30)—1816/30—2.39—0.584
16 AWG (19/29)—1619/29—2.64—0.584
14 AWG (19/27)—1419/27—2.95—0.584
12 AWG (19/25)—1219/25—3.58—0.66
10 AWG (19/23)—1019/23—4.42—0.787

Source: awcwire.com (2026-10-30)

SXL — SAE J1128 · XLPE (cross-linked polyethylene) · -51 to +125 °C
Sizemm²AWGStrandingOD min (mm)OD nom. (mm)OD max (mm)Wall (mm)
20 AWG (7/28)—207/28—2.44—0.737
18 AWG (16/30)—1816/30—2.72—0.762
16 AWG (19/29)—1619/29—3—0.762
14 AWG (19/27)—1419/27—3.56—0.889
12 AWG (19/25)—1219/25—4.06—0.94
10 AWG (19/23)—1019/23—4.88—1.092

Source: awcwire.com (2026-10-30)

UL1007 — UL AWM style 1007 (also style 1569; CSA TR-64) · PVC · -40 to +105 °C
Sizemm²AWGStrandingOD min (mm)OD nom. (mm)OD max (mm)Wall (mm)
30 AWG (7/38)—307/381.071.121.170.406
28 AWG (7/36)—287/361.141.191.240.406
26 AWG (7/34)—267/341.241.31.350.406
24 AWG (7/32)—247/321.371.421.470.406
22 AWG (7/30)—227/301.521.571.630.406
20 AWG (10/30)—2010/301.71.751.80.406
18 AWG (16/30)—1816/301.962.012.060.406
16 AWG (26/30)—1626/302.292.342.390.406

Source: alphawire.com (2026-10-30)

UL1015 — UL AWM style 1015 (also style 1230; MTW/TEW on most sizes) · PVC · -40 to +105 °C
Sizemm²AWGStrandingOD min (mm)OD nom. (mm)OD max (mm)Wall (mm)
24 AWG (7/32)—247/322.132.242.340.813
22 AWG (7/30)—227/302.292.392.490.813
20 AWG (10/30)—2010/302.462.572.670.813
18 AWG (16/30)—1816/302.722.822.920.813
16 AWG (26/30)—1626/303.053.153.250.813
14 AWG (41/30)—1441/303.43.513.610.813
12 AWG (65/30)—1265/303.733.843.940.813
10 AWG (105/30)—10105/304.574.674.780.813

Source: alphawire.com (2026-10-30)

M22759/16 — SAE AS22759/16 (MIL-W-22759/16) · ETFE (ethylene tetrafluoroethylene) · -55 to +150 °C
Sizemm²AWGStrandingOD min (mm)OD nom. (mm)OD max (mm)Wall (mm)
24 AWG (19/36)—2419/361.09—1.19—
22 AWG (19/34)—2219/341.27—1.37—
20 AWG (19/32)—2019/321.47—1.57—
18 AWG (19/30)—1819/301.75—1.85—
16 AWG (19/29)—1619/291.96—2.06—
14 AWG (19/27)—1419/272.31—2.41—
12 AWG (37/28)—1237/282.82—2.97—
10 AWG (37/26)—1037/263.45—3.61—

Source: awcwire.com (2026-10-30)

M22759/32 — SAE AS22759/32 (MIL-W-22759/32) · XL-ETFE (cross-linked ethylene tetrafluoroethylene) · -55 to +150 °C
Sizemm²AWGStrandingOD min (mm)OD nom. (mm)OD max (mm)Wall (mm)
26 AWG (19/38)—2619/380.76—0.86—
24 AWG (19/36)—2419/360.89—0.99—
22 AWG (19/34)—2219/341.04—1.14—
20 AWG (19/32)—2019/321.22—1.32—
18 AWG (19/30)—1819/301.47—1.57—
16 AWG (19/29)—1619/291.68—1.78—
14 AWG (19/27)—1419/272.08—2.24—
12 AWG (37/25)—1237/252.54—2.69—

Source: awcwire.com (2026-10-30)

IEC 60757 colour codes

Two-letter codes used on drawings and wire lists. The swatches are screen colours only. (in use; edition not verified (source names IEC 60757 of January 1983 and DIN IEC 60757:1986-07 as latest))

CodeColourGerman
BKblackschwarz
BNbrownbraun
RDredrot
OGorangeorange
YEyellowgelb
GNgreengrün
BUblueblau
VTvioletviolett
GYgreygrau
WHwhiteweiß
PKpinkrosa
TQturquoisetürkis
GNYEgreen-yellowgrün-gelb
GDgoldgold
SRsilversilber

Source: de.wikipedia.org (2026-10-30)

DIN 47100 core colours (1–44)

For multi-core cables: one colour for cores 1–10, base colour plus stripe or ring from core 11. The first colour is the base. DIN 47100 was withdrawn in 1998 and is still widely used.

CoreColourGerman
1whiteweiß
2brownbraun
3greengrün
4yellowgelb
5greygrau
6pinkrosa
7blueblau
8redrot
9blackschwarz
10violetviolett
11grey-pinkgraurosa
12red-bluerotblau
13white-greenweißgrün
14brown-greenbraungrün
15white-yellowweißgelb
16yellow-browngelbbraun
17white-greyweißgrau
18grey-browngraubraun
19white-pinkweißrosa
20pink-brownrosabraun
21white-blueweißblau
22brown-bluebraunblau
23white-redweißrot
24brown-redbraunrot
25white-blackweißschwarz
26brown-blackbraunschwarz
27grey-greengraugrün
28yellow-greygelbgrau
29pink-greenrosagrün
30yellow-pinkgelbrosa
31green-bluegrünblau
32yellow-bluegelbblau
33green-redgrünrot
34yellow-redgelbrot
35green-blackgrünschwarz
36yellow-blackgelbschwarz
37grey-bluegraublau
38pink-bluerosablau
39grey-redgraurot
40pink-redrosarot
41grey-blackgrauschwarz
42pink-blackrosaschwarz
43blue-blackblauschwarz
44red-blackrotschwarz

Source: elandcables.com (2026-10-30)

Writing a two-colour wire

How sources write a base colour with a stripe. Where a source says so, the first colour is the base.

Written asMeans
WHGNwhite base with green stripe or ring (DIN 47100 core 13)
base colour + ring colourfirst colour = base colour of core insulation, second or third = printed ring colour
GNYEgreen-yellow (a single IEC 60757 code of its own)
BKWHtwo IEC letter codes written together in an order code (German SWWS)
WHITE/BLACKslash between two full colour names (hook-up wire colour list)
BLACK WITH WHITE STRIPEbase colour named first, stripe colour after 'with ... stripe'
YRyellow with red stripe (letter of base colour first, then stripe)

Source: elandcables.com (2026-10-30)

Questions

Is 18 AWG the same as 0.75 mm²?
No. 18 AWG is 0.823 mm² of copper; 0.75 mm² lies between 19 AWG (0.653 mm²) and 18 AWG. Using one for the other is a decision for the drawing's owner, not a conversion: the terminal's wire range and the current capacity both depend on it.
Why do two 0.5 mm² wires have different diameters?
The insulation. FLRY-B is a thin-wall PVC wire; TXL, GXL and SXL are XLPE wires with thin, medium and thick walls. The outside diameter decides the seal and the grommet, so take it from your wire's own sheet.
Which colour code should my wire list use?
IEC 60757 letter codes (BK, BN, RD …) are short and unambiguous in every language. Zorowire's importer also reads German, Romanian and Polish colour names and the old DIN 47002 abbreviations.
Is the AWG table for stranded wire too?
It is the AWG definition: solid round copper. A stranded conductor of the same gauge has its own area, given in the wire maker's sheet.